 Single Cylinder Pinch Valve Pinch Valve - Fail Safe
Normally Closed - Air to open - Spring Return
'The best valve for silo safety systems' Normally Closed Pinch Valve Datasheet (2 MB)
How it works
The normally closed Pinch Valve operates in the opposite way to the standard Pinch Valve. Air pressure is used to open the valve and when the air is taken off the valve closes in the fail safe position. When open, the Normally Closed Pinch Valve allows full unobstructed flow.
 single cy1.bmp) Normally Closed Pinch Valve Sizes
Single Cylinder 15mm to 65mm Double Cylinder 80mm - 200mmPinch Valve Body Aluminum
Flange Connections
PN10/16
Sleeve Materials
Natural Rubber (Standard), EPDM & Neoprene
Valve Function
 Double Cylinder Normally Closed Pinch Valve Single Cylinder requires 3-4 BAR to open Double Cylinder requires 5.5 - 6 BAR to open
AccessoriesSolenoid Valve, pressure regulators & Limit switches
Advantages
Straight through clear bore 100% leak tight seal True bore - No blockages Visual open/close indicator Bi-directional Easy and low cost maintenance (Fitting instructions available on request) Quick/Efficient deliveries from largest UK Pinch Valve stock Full technical back up If you have any questions regarding this product, please contact AKO UK Ltd on 01327 312747 or
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
|